2024年澳门开彩结果历史记录
AMI System Solution
AMI System Solution


Functions
Administration

Meter Administration
Concentrator Administration
Monitoring of System Components Replacement History
Monitoring of Command and Parameter History of System Components
Defining of Roles and Users/User Groups
Access Control to System Components and AMR Centre
Administration of reporting functions of AMI Centre
Regular Automatic Backup of All Data At the Desired Time

Data Reading/Collection and Archiving

Reading of Individual Concentrator/meter

Reading of the Group of Concentrators/Meters

Automated Reading According to the Sequence

Reading On Request

Periodical Reading on Request

Special Reading on Request

Data collected automatically according to the sequence set in advance include the following

   Daily Register Values

   Meter States

   Electricity Quality Log

   Event Log

   Load Profile

   Hourly Register Values

   State of Monthly Accounting Registers

   Time and Date


Data collected from the meter on request including:

   Effective Voltage Values Per Phases At the Moment of Reading

   Effective Current Values Per Phases At the Moment of Reading

   Current Power–(Load Power At the Moment of Reading)

   Tariff Programmer

   Integration Period for 15-Minute Maximum Power

   Consumption Management Parameters

   Parameters for Voltage Thresholds Within Electricity Quality Log

   Parameters or Time Intervals of Profiles

   Parameters for Registers Within Profiles

   Parameters Related to the Presentation On Meter Display

   Archive States of Accounting Registers

   Current State of Bi-stabile Switch

   Meter Software Version

   Factory Number and Type of Meter


 Data read according to the sequence from the concentrator including:

   Statistics of Communication / Emergency and Regular Reports


 Data read from the concentrator upon the request including:

   Concentrator Data Archive

   Reading Programmes/Sequences

   Management/Parameterisation Programmes/Sequences

   Programmes/Sequences Execution Priorities

   Communication Routes

   Concentrator Response Time and Frequency Parameters

   Communication Parameters of the Concentrator

   Current Date and Time

   Other Concentrator Parameters

   Concentrator Software Version

   Records on Concentrator Parameter Changes and Adjustments

Reporting functions

Reports with Analysis of Statuses and Alarms

 Reports on Electricity Quality

 Reports Related to Parameterization and Management

 Communication Reports

 Control Reports

 Reports Generated by the Concentrator

Data and Information Exchange with Other Information Systems and Subsystems of Electric Utility Robust protocol library for various types of DCUs and electronic energy meters, DLMS/COSEM, IEC61870-5-102 compliant